Setting Up the EEI Prover
1. Log on to the EEI prover application.
2. Clamp the Intelis Gas Meter to the EEI prover.
3. Select the Meter tab and choose ITRON from the Manuf drop-down list.
Important! If ITRON is not in the Manuf. drop-down list, contact EEI Prover
Systems for help in adding ITRON to your EEI Systems Prover.
4. Select Intelis 250, Intelis 250 TC, or the name for the Intelis Gas Meter designated by your
company from the Type drop-down list.
Important! If the correct Intelis Gas Meter type is not in the Type drop-down list,
contact EEI Prover Systems for help adding the correct meter type to your EEI
Systems Prover.
5. Click the Options tab.
6. The Meter Information > Test Options window opens.
7. Select Eye for the Test Options Sensor.
08 July 2020 815-0154-00 REV 000 Itron, Inc. Page 52 of 66
Intelis Gas Meter Proving and Setup Guide
6 Proving the Intelis Gas Meter Using the Energy Economics (EEI)
Proving System