a) Standard programs for Ivoclar Vivadent
materials
IPS d.SIGN
IPS InLine
IPS Empress Esthetic
IPS e.max Press
IPS e.max Ceram
Various Add-On materials
When the furnace is delivered ex
works, the standard programs already
contain the recommended material
parameter settings. Moreover, the
programs are write-protected. Please
refer to the respective list of parameters
in Chapter 10.
However, the parameters can be changed and
overwritten at any time, if the programs are to be
used for other purposes. Therefore, these
programs are also available as free programs.
b) Free programs
Free, individually adjustable programs
The programs are designed in such a way that
they can be either used as conventional, one-stage
programs or as two-stage programs, if required.
The mode can be changed via the symbol (one- or
two-stage program) by using the + or – key.
c) Special programs
Various test programs are available. Please refer
to chapter 5.5.5 Special programs.
5.4 Adjustable parameters and possible value ranges
Symbol Parameter Value range Value range
P Program number P 001–200
B Stand-by temperature 100–700 °C 212–1292 °F
S Closing time (min : sec) 00:18–30:00
Pre-vaccum (min : sec) 01:00–05:00
tÚ Temperature increase rate 10–140 °C/min 18–252 °F/min
T Holding temperature 100–1200 °C 212–2192 °F
H Holding time (min : sec) 00.01–60:00
V1 Vacuum on 0 or 1–1200 °C 0 or 34–2192 °F
V2 Vacuum off 0 or 1–1200 °C 0 or 34–2192 °F
L Long-term cooling 0 or 50–1200 °C 0 or 122–2192 °F
tL Cooling temperature rate 0 or 1–50 °C 0 or 2–90 °F/min
t2Ú Temperature increase rate 10–140 °C/min 18–252 °F/min
2
nd
stage
T2 Holding temperature 2
nd
stage 100–1200 °C 212–2192 °F
H2 Holding time 2
nd
stage (min : sec) 00.01–60:00
V1 2 Vacuum on temp. 2
nd
stage 0 or 1–1200 °C 0 or 34–2192 °F
V2 2 Vacuum off temp. 2
nd
stage 0 or 1–1200 °C 0 or 34–2192 °F
VT Pre-drying temp. 100–700 °C 212–1292 °F
VH Pre-drying holding time (min :sec) 00:00–60:00
HV Holding time Vacuum (min : sec) 00:01–60:00
Pre-drying temperature 0 or 100–700 °C 0 or 212–1292 °F
Pre-drying time 00:00-60:00
Automatic plausibility check
The furnace is equipped with an automatic plausibility check function. The parameters
(e.g. T 960 but L 1000) are checked upon each program start. In case of contradictory
parameter combinations, the program stops automatically and the respective error
number is indicated.
List of parameters
In this screen, the arrow keys can be used to navigate within the list (including
program number). An active numeric value can be edited using the – / + keys or the
numeric keypad.
An active symbol parameter can only be changed using the – / + keys.