Error ERR Conti- Error Message Text
No. nuation
possible
25 System Write error in the 46 Error while writing firing group data to the internal memory.
firing group memory
26 System Read error in the 47 Error while reading the firing group data from the internal memory.
firing group memory
27 System Checksum error in the 48 Invalid checksum of the memory for firing group data - the firing group data are written to the internal
firing group memory memory using the original values.
28 System OT1 <> OT2 54 no Error in the temperature measuring circuit! Contact your local Ivoclar Vivadent Service Center.
plausibility check:
**,***
OT1 = OT2 +/- 10°C
29 System Temperature in the furnace 56 Temperature in the furnace base is lower than 1 °C. Bring the furnace base to a higher operating temperature.
base is lower than 1 °C
30 System Program start blocked 103 Starting a program is not possible due to a technical malfunction.
31 System Incorrect time settings 107 The clock settings are incorrect. Please set a correct date and a correct time!
(date / time)
32 Entry Timer activated – unit into 106 The program cannot be started, because the unit was put into stand-by mode by the timer (heating turned
stand-by mode off). Deactivate the timer or extend the time frame to be able to execute programs.
33 System Print error 108 An error occurred during printing.
34 Entry HV > H (H2) 110 Enter a lower value for HV or a higher value for H (H2)
35 Note Maximum number of firing 111 The maximum number of firing program protocol entries has been reached. For the next protocol, an existing
program protocol entries entry will be deleted / overwritten.
reached
36 Entry "Share of the holding time 120 Activate the vacuum during the holding time Tx or deactivate HV..
with vacuum" is activated,
but Vx2 does not
correspond to Tx or Tx+1
37 System Error pressing time 500 Max. pressing time exceeded
38 System Error press position 504 Max. position exceeded
39 System Error press force 505 Max. press force exceeded.
40 System Error press drive initalized 513 Press drive is not initialized. Please switch the furnace off and on again.
41 System Error press drive 514 Technical error in press drive
42 Inform. Error muffle crack 520 CDS Crack Detection System has been activated. The program has been aborted and the press plunger has
been moved backwards. CDS could probably save your restorations from muffle cracks. Please check your
restorations before you continue your working progress
43 Inform. Error muffle crack 521 CDS Crack Detection System has been activated. The program has been aborted and the press plunger has
been moved backwards. CDS could probably save your restorations from muffle cracks. Please check your
restorations before you continue your working progress
44 Inform. Error muffle crack 522 CDS Crack Detection System has been activated. The program has been aborted and the press plunger has
been moved backwards. CDS could probably save your restorations from muffle cracks. Please check your
restorations before you continue your working progr
45 Entry T is > B + 200°C at the 526 Firing chamber is too hot for the start of a IPF press program.
start of a IPF press progr.
46 Entry IPF press program para- 527 The set IPF press program parameters are not plausible.
meters not plausible
47 Entry T is < 350°C at the start 528 The furnace is too deeply cooled down for the start of a IPF press program.
of a IPF press program
48 Note IPF press program 529 The temperature during the IPF press program does not comply with the specifications. The program
Error temperature may be continued nonetheless.
49 System Error during logging of 530 An error has occurred during logging of press program data. The storage medium might be full.
press program data
50 System Supply voltage outside the 700 The supply voltage is outside the acceptable range. Check the supply voltage.
acceptable range
51 System Start-up aborted due 701 no The self-test of the furnace was interrupted by an error. It is not possible to work with the furnace! Switch
to an error *** the furnace off and on again, once the error has been rectified.
52 System Brief power failure during a 702 A firing program in progress was interrupted by a brief power failure. The program is continued!
firing program in progress
53 System Power failure during a 703 A firing program in progress (started from the USB memory stick) was interrupted by a power failure.
firing program from the The program could not be continued, since the USB memory stick is no longer present!
memory stick in progress –
memory stick no longer
present.
54 System Prolonged power failure 704 An overnight program (firing program) in progress was interrupted by a prolonged power failure.
during an onvernight The overnight program is continued!
program in progress
55 System Reading and processing 705 no Error during measuring the supply voltage. Contact your local Ivoclar Vivadent Service Center.
supply voltage
**,***
56 System
Reading the power frequency
706 Error during measuring the supply voltage. Contact your local Ivoclar Vivadent Service Center.
57 System Incorrect supply voltage 707 The furnace is operated with the incorrect supply voltage. Make sure that the furnace is operated with the
supply voltage indicated on the rating plate.
58 System Final vacuum value not 800 The required final vacuum value cannot be reached. Check the vacuum pump.
reached
59 System Vacuum drop 801 An unacceptable vacuum drop has occurred.