4.3 Assembly
Assembling the furnace is very easy and involves only few steps. Before you start assembling the furnace, make sure that
the voltage indicated on the rating plate complies with the local power supply. If this is not the case, the furnace must not
be connected.
Step 1:
Mounting the cooling tray (2)
Remove the two fastening screws (1) of the cooling tray and the
transport protection of the infrared camera.
Secure the cooling tray (2) with the two screws (1).
Step 2:
Mounting the firing plate
Place the firing plate (22) on the firing plate holder (23). If placed
correctly, the bottom of the firing plate is automatically centered in
the firing plate holder.
Place the cooling tray (2) on the frame plate (24). Make sure that the
cooling tray is correctly positioned on the frame plate.