conMIG 300
Operating manual Page 21
19. Technical data
conMIG 300
Power source
Supply voltage, 50/60 Hz 400 V, 3-phase, +/- 10%
Drawing of current Imax = 19 A, Ieff = 11A
Fuse 16 A slow
Max. power draw 13 kVA
Set-point range 40 - 300 A
Operating voltage 16 - 29 V
Open-circuit voltage 20 - 45 V
Voltage steps 12
Duty cycle 30 % (40°C) 300 A / 29 V
Duty cycle 60 % (40°C) 230 A / 25.5 V
Duty cycle 100 % (40°C) 200 A / 24 V
System of protection IP 23
Insulation category H (180° C)
System of cooling F
Weight 78 kg
Dimensions L x W x H (mm) 900 x 490 x 740
Noise emission < 70 dB(A)
Wire feed
Wire feed motor with 42 V, 50 W
Wire feed speed 1,0 - 24 m/min
Diameter of wire 0.8 - 1.2 mm
Authorized for welding under increased electrical hazard
Manufactured in accordance with EN 60 974-1 and EN 60 974-10
Generator operation:
The generator must have 30% more power as the welding unit.
Example: 13kVA (unit) + 30% = 17kVA. The generator for this unit must have 17kVA.
A generator with less power will damage the Jäckle welding unit as well as the generator himself
and is disallowed.
20. Environmental conditions
The power source must be operated at a temperature between -10°C to +40°C and a relative humidity of 50% at
40°C or up to 90% at +20°C. The ambient air must be free of unusual amounts of dust, acids, corrosive gases or
substances, etc., unless they occur during welding.
To prevent damage to the machine the temperature around the machine is controlled.
If this temperature is below -10°C or above + 40°C, the following text appear on the display and the machine can
not be started:
t°C - int – ‚measured temperature value’
Only when the temperature is in the prescribed range, the welding operation can be started.