EasyManua.ls Logo

Jackson CONSERVER XL-E - Operating Capacities

Jackson CONSERVER  XL-E
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
07610-003-92-84-Q
6
Model Designation: XL-E XL-E-LTH XL HH
Operating Capacity:
Racks per Hour 39 39 39
Dishes per Hour 975 975 975
Glasses per Hour 1404 1404 1404
Tank Capacity (Gallons):
Wash Tank 1.02 (40.2 GPH) 1.02 (40.2 GPH) 1.61 (62.8 GPH)
Electrical Loads (as applicable):
Wash Motor HP 1 1 1
Operating Times (seconds):
Normal Medium Heavy
Wash 42 42 100 280 43
Rinse 25 25 25 25 25
Dwell 20 20 20 20 18
Water Temperatures (°F):
Minimum Wash Temperature 120 120 120
Recommended Wash Temperature N/A 140 N/A
Minimum Rinse Temperature 120 120 120
Recommended Rinse Temperature N/A 145 N/A
Minimum Incoming Water Temperature 120 110 120
Other Water Requirements:
Water Flow Pressure (PSI) 20 +/- 5 20 +/- 5 20 +/- 5
Flow Rate Minimum (GPM) 6.18 6.18 9.66
Water Line Size (NPT) 3/4” 3/4” 3/4”
Drain Line Size (NPT) 2” 2” 2”
Minimum Chlorine Required (PPM) 50 50 50
Always refer to the machine data plate for specic electrical and water requirements.
The material provided on this page is for reference only and is subject to change without notice.
OPERATING CAPACITIES
SPECIFICATIONS
NOTICE