3
07610-003-62-15-Q
Operating Capacity: Delta
®
1200 Delta
®
115
Glasses per Hour 1200 1200
Operating Cycle:
Total Cycle Time 1200 1200
Tank Capacity (Gallons): 3.0 3.0
Wash Pump Capacity (GPM): 55 55
Water Temperatures (°F):
Minimum Wash Temperature 120 130
Minimum Rinse Temperature 75 75
Other Water Requirements:
Cold Water Flow Pressure (PSI) 8-12 8-12
Hot Water Flow Pressure (PSI) 20 ± 5 20 ± 5
Gallons per Hour 10.0 10.0
Water Line Size (NPT) 1/2" 1/2"
Drain Line Size (NPT) 1 1/2" 1 1/2"
Minimum Chlorine Required (PPM) 50 50
Electrical Loads (as applicable):
Wash Motor (HP) 0.1 0.1
Wash Heater (kW) 2.7 (208 V)/3.3 (230 V) 1.3
NOTE: Always refer to the machine data plate for specic electrical and
water requirements. The material provided on this page is for reference
only and is subject to change without notice.
OPERATING PARAMETERS
SPECIFICATIONS
i