SERVICE PROCEDURES
SERVICE
CHEMICAL FEEDER
PUMP MOTOR
REPLACEMENT
CAUTION! Many of the instructions and steps within this document
require the use of tools. Only authorized personnel should ever
perform any maintenance procedure on the dishmachine!
PREPARATION
Power must be secured to the unit at the service breaker. Tag or lock-out
the service breaker to prevent accidental or unauthorized energizing of the
machine.
Ensure that incoming water to the machine is secured either by use of a
shut-off valve or disconnecting the incoming water line.
The unit must be drained completely with the drain stopper removed.
TOOLS REQUIRED
Phillips Screwdriver
Needle-nose Pliers
Wire Cutters
Wire Strippers
Crimping Tool
IMPORTANT NOTES
Read these instructions thoroughly before attempting this maintenance task.
Become familiar with the parts and what actions need to be taken. This will
save time in the long run!
These instructions show steps on only one of the three motors. However, the
steps are the same for each one.
STEPS
1. Remove the front door.
2. Remove the electrical box cover with the phillipshead screwdriver.
3. The cover must be laid-down close to the control box because of the
attached wires. Be careful not to yank out or damage any of the wires as you
move the cover.
!
CAUTION
These machines come
equipped with chemical
feeder pumps to ensure
proper warewashing
results. Occasionally,
the motors operating
these pumps might need
replacing.
The instructions provided
here are for maintenance
personnel only.
Unauthorized persons
should not attempt any
of the steps contained in
these instructions.