Cartridge Pool Filters - CL and CV Series Filters
3.5 Clamp Installation
1. Be certain the o-ring is in position in the lower
WDQNKDOI3UHVVWKH¿OWHUOLGRYHUWKHORZHUKDOI
sandwiching the o-ring between the two halves.
 +ROGLQJWKHHQGVRIWKH¿OWHUFODPSDSDUWSRVLWLRQ
WKHKLQJHGVHJPHQWRIWKH¿OWHUFODPSRYHUERWK
XSSHUDQGORZHUWDQNÀDQJHV%ULQJWKHHQGVRIWKH
¿OWHUFODPSWRJHWKHU
 3ODFHWKH7QXWDQGWKUHDGHGURGDVVHPEO\LQWR
WKHFODPS%HVXUHWKH7QXWLVVHDWHGLQWKH
clamp in the proper orientation (See Fig. 9).
 8VHDVRFNHWRQWKHWLJKWHQLQJQXWXQWLOWKH
clamp ring halves touch each other, or are within
6HH)LJbut do not overtighten as the
clamp can break. If unable to tighten as indicated,
GRQRWRSHUDWHWKH¿OWHUDQGcall a service
technician immediately.
 $IWHUWKH¿UVWZHHNRIRSHUDWLRQFKHFNWKHFODPS
and retighten if necessary.
 &KHFNWKH¿OWHUFODPSDWOHDVWRQFHDPRQWK
Figure 9. Filter Clamp Ring
Clamp Ring
"T" Nut and
Threaded Rod
Tightening Nut
w/ Shoulder
 &KHFNWKDWWKHGUDLQSOXJIRU&/¿OWHUVRUGUDLQ
FDSIRU&9¿OWHUVLVLQSODFHDQGWLJKW
3. Check that the tank clamp is correctly seated and
tight (See Figs. 9 and 10).
 2SHQWKHSXPSKDLUOLQWSRWOLGDQG¿OOWKHSXPS
basket with water to prime the system. Replace the
lid. (You may have to do this several times on new
and seasonal start-ups.)
5. Completely open the air release valve on the
JDXJHDLUUHOHDVHDVVHPEO\E\WXUQLQJWKHNQRERQ
the back of the assembly fully counterclockwise
(do not remove the knob).
 %HVXUHWRRSHQDQ\¿OWHULVRODWLRQYDOYHVWKDW
were installed in the system.
7. 6WDQGFOHDURIWKH¿OWHUand start the pump to
circulate water through the system. When a steady
stream of water starts to come out of the air release
valve, close the valve.
8. Watch the pressure gauge to be sure that the
pressure does not exceed 50 psi (with clean
cartridges). If the pressure approaches 50 psi,
immediately turn the pump off and clean the
¿OWHUFDUWULGJHVVHH6HFWLRQ,IWKHSUHVVXUH
UHPDLQVKLJKDIWHUFOHDQLQJWKH¿OWHUUHIHUWRWKH
troubleshooting guide in Section 8 for possible
causes and solutions.
WARNING
Follow these instructions carefully.
Improper clamp installation can cause
the filter lid to be blown off, which can
result in death, serious personal injury,
or property damage.
CAUTION
DO NOT operate filter at water temperatures above
)&:DWHUWHPSHUDWXUHVDERYHWKH
manufacturer's recommendations will shorten the
life span of the filter and void the warranty.
WARNING
NEVER start pump while standing
ZLWKLQILYHIHHWRIWKHILOWHU6WDUWLQJ
the pump while there is pressurized air
in the system can cause the filter lid to
be blown off, which can cause death,
serious personal injury or property
damage.
WARNING
NEVER operate the filter system at
PRUHWKDQSVLRISUHVVXUH2SHUDWLQJ
WKHILOWHUV\VWHPLQH[FHVVRISVLFDQ
cause the filter lid to be blown off, which
can cause death, serious personal injury
or property damage.
Section 4. Start-Up and Operation
NOTE
This section applies to both new pool and
seasonal start-up.
1. Turn off the pump. Switch off the circuit breaker
to the pump motor.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jandy CL Versa-Plumb Series and is the answer not in the manual?

Jandy CL Versa-Plumb Series Specifications

General IconGeneral
BrandJandy
ModelCL Versa-Plumb Series
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals