EasyManuals Logo

Jandy Stealth SHPM User Manual

Jandy Stealth SHPM
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
1.2 Pool Pump Suction Entrapment Prevention Guidelines
WARNING
Pump suction is hazardous and can trap and drown or disembowel bathers. Do not use or operate swim-
ming pools, spa, or hot tubs if a suction outlet cover is missing, broken, or loose. The following guidelines
provide information for pump installation that minimizes the risk of injury to users of pools, spas, and hot tubs:
Entrapment Protection - The pump suction system must provide protection against the hazards of suction
entrapment.
Suction Outlet Covers - All suction outlets must have correctly installed, screw-fastened covers in place. All
suctionoutlet(drain)assembliesandtheircoversmustbeproperlymaintained.Suctionoutlets(drain)assem-
bliesandtheircoversmustbelisted/certiedtothelatestversionofANSI
®
/ASME
®
A112.19.8 or its successor
standard, ANSI/APSP-16. They must be replaced if cracked, broken, or missing.
Number of Suction Outlets Per Pump-Provideatleasttwo(2)hydraulically-balancedmaindrains,withcov-
ers,assuctionoutletsforeachcirculatingpumpsuctionline.Thecentersofthemaindrains(suctionoutlets)on
anyone(1)suctionlinemustbeatleastthree(3)feetapart,centertocenter.SeeFigure1.
The system mustbebuilttoincludeatleasttwo(2)suctionoutlets(drains)connectedtothepumpwhenever
thepumpisrunning.However,iftwo(2)maindrainsrunintoasinglesuctionline,thesinglesuctionlinemaybe
equippedwithavalvethatwillshutoffbothmaindrainsfromthepump.Thesystemshallbeconstructedsuch
that it shall not allow for separate or independent shutoff or isolation of each drain. See Figure 1.
Morethanone(1)pumpcanbeconnectedtoasinglesuctionlineaslongastherequirementsabovearemet.
Water Velocity - The maximum water velocity through the suction outlet assembly and its cover for any suc-
tionoutletmustnotexceedthesuctionttingassemblyandit’scover’smaximumdesignowrate.Thesuction
outlet(drain)assemblyanditscovermustcomplywiththelatestversionofANSI/ASMEA112.19.8,thestandard
for Suction Fittings For Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs, or its successor standard,
ANSI/APSP-16.
If100%ofthepump’sowcomesfromthemaindrainsystem,themaximumwatervelocityinthepumpsuc-
tionhydraulicsystemmustbesix(6)feetpersecondorless,evenifone(1)maindrain(suctionoutlet)iscom-
pletelyblocked.Theowthroughtheremainingmaindrain(s)mustcomplywiththelatestversionofANSI/ASME
A112.19.8 or its successor standard, ANSI/APSP-16, the standard for Suction Fittings For Use in Swimming
Pools, Wading Pools, Spas, and Hot Tubs.
Testing and Certication - Suction outlet assemblies and their covers must have been tested by a nationally
recognized testing laboratory and found to comply with the latest version of ANSI/ASME A112.19.8 or its succes-
sor standard, ANSI/APSP-16, the standard for Suction Fittings For Use in Swimming Pools, Wading Pools, Spas,
and Hot Tubs.
Fittings-Fittingsrestrictow;forbestefciencyusefewestpossiblettings(butatleasttwo(2)suctionoutlets).
Avoidttingswhichcouldcauseanairtrap.
PoolcleanersuctionttingsmustconformtoapplicableInternationalAssociationofPlumbingandMechanical
Ofcials(IAPMO)standards.
SUCTION HAZARD. Can cause serious injury or death. Do not use this pump for
wading pools, shallow pools or spas containing bottom drains, unless the pump is
connected to at least two (2) functioning suction outlets.
WARNING
CAUTION
The 3-phase SHPF series pumps utilize non-thermally protected motor assemblies. NRTL Listed Motor Controller
withinternalmotorrunningoverloadprotectionorexternalmotorrunningoverloadarerequiredduringthefinal
installation of the pump assembly. Overloads shall be set at a maximum of 125% of the full-load current rating of
the pump motor assembly.
Page 5
ENGLISH
Jandy
®
Pro Series Stealth
Pumps
|
Operation Manual

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jandy Stealth SHPM and is the answer not in the manual?

Jandy Stealth SHPM Specifications

General IconGeneral
BrandJandy
ModelStealth SHPM
CategoryWater Pump
LanguageEnglish

Related product manuals