EasyManua.ls Logo

Janome MC350E - Adjusting Tension Release Mechanism

Janome MC350E
55 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
MC350E
Adjusting Tension Release Mechanism
When the presser foot lifter is raised, the tension release mechanism should work correctly.
If not, adjust as follows.
1 Remove the front cover unit. (see page 6)
2 Lower the presser foot lifter, set the thread tension dial
at “9” and loosen the Screw .
3 Adjust the play between the tension release rod (2)
and the Spring holder approximately 0.3 - 0.5
mm and tighten the Screw .
4 Raise the presser foot lifter, turn the thread tension
dial from “9” to “0”, make sure the tension disc
should open 1.0 mm .
5 Reattach the front cover unit.
Screw
Tension release rod (2)
Play (0.3 - 0.5 mm)
Spring holder
Tension disc
Clearance (approximately 1.0 mm)
B
A
C
D
A
B D
A
E
E
F
A
B
C
B
D
E
F
F