TO CHANGE BH SENSOR UNIT TO REMOVE
1. Remove the top cover unit (see page 3).
2. Loosen the screw and remove the BH sensor from the sensor fixing plate.
3. Pull out the BH sensor connector from board F and pull out the cord from the cord guide
(1), (2). Then change the BH sensor unit.
TO ATTACH
4. To attach the BH sensor, follow the above procedure in reverse.
NOTE:
Make sure the BH sensor and shielding plate do not touch when attaching the BH sensor.