14
DESCRIPTION OF CONTROLS - JASIC MIG EM-160 and EM-200
Front view Jasic MIG EM-160C and EM-200C
1. Digital user control panel (see lower
down for further informaon)
2. Wireless remote control (oponal)
3. "+" Output terminal*, The connecon
for the torch in MIG mode
4. Euro outlet trailing cable plug, this
plug is used to determine the polarity
of the torch euro outlet socket
5. MIG torch outlet, The connecon used
to connect the euro style MIG torch
6. "-" Output terminal*, The connecon
for the work return lead in MIG mode
7. Wired remote control 9 pin socket
8. Machine mains power cable
9. Shielding gas inlet hose
* Panel socket size is 35/50mm
Rear view Jasic MIG EM-160C and EM-200C
10. Carry handle
11. Shielding gas inlet (quick ng)
12. ON/OFF power switch
13. Rear panel with integrated cooling vents
14. Input power cable
Front control panel view Jasic MIG EM-160C and EM-200C
15. Remote control enable switch and
indicator
16. Synergic control ON/OFF switch and
indicator
17. Wire Inch Buon and indicator
18. Gas Test Buon and indicator
19. Welding Mode selecon area
20. MIG Parameter selecon area
21. Digital display windows and controls
22. Warning indicators
23. MIG and MIG Spool Gun selecon
switch and indicators
24. 2T and 4T selecon switch and
indicator
For further informaon of the control
panel, please see page 19