After successful pairing, the parameters can be adjusted by the wireless remote controller.
(2) Disconnect wireless remote controller
After the remote controller has been successfully paired, press and hold the remote control
function key on the panel or the pairing key on the wireless remote controller for
2s, and the connection of the wireless remote controller will be disconnected. After
disconnecting, the display window of the welder will display "FAL", and the green indicator
of the wireless receiver module will remain on.
i. Selection of Synergic MIG function
1) In MIG mode, press the "Synergic" function key to enable or disable the function.
2) If the indicator is on, it indicates that the "Synergic" function is enabled. If it is off, it
indicates that the function is disabled, and MIG is in separate mode.
3) In "Synergic" mode, the machine automatically matches the welding voltage (arc length)
and inductance according to the welding type and welding wire diameter selected and the set
current (or wire feed speed, plate thickness), and the user can adjust the voltage or
inductance as required.
(4) In separate mode, the wire feed speed, voltage and inductance can be set separately.
j. Inching function
1) In MIG mode, press the inching key to start wire feeding and release the key to stop
wire feeding.
2) If the indicator is on, it indicates that the inching is enabled to start wire feeding, and the
wire feed speed depends on the preset value.
k. Gas check function
1) In MIG or Lift TIG mode, press the gas check function key to start gas supply and
press the key again in 20s to stop gas supply;
2) If the indicator is on, it indicates that the gas check function is enabled and the gas