3) .Alarm voltage
Set the value of the primary alarm voltage and secondary alarm
voltage.
When the battery voltage detected by the flight control reaches the
first-level alarm voltage, the flight control LED flashes yellow three
times; when the detection voltage reaches the second-level alarm
voltage, the yellow light flashes quickly, and the flight control will
trigger the low-voltage protection behavior set by the user.
4). Calibration voltage
When the flight control detection voltage is different from the actual
battery voltage, the flight control measurement voltage needs to be
calibrated. You need to enter the actual voltage of the battery in the
“Measured Voltage” column to calibrate the flight control
voltage. Make sure the current voltage displayed by the flight
controller is consistent with the actual battery voltage.
5) .One touch return
Altitude: The lowest flight altitude when returning with one touch.
Landing speed: The speed of the return home landing.
Note: When setting the return altitude, please set a reasonable altitude in
accordance with the current flight environment to avoid obstacles during the return
journey.
3 Water pump settings
Click to enter the advanced interface of the assistant software, and
select the pump setting in the upper menu bar. As shown in the
figure, select the pump type and channel settings according to the
actual situation of the pump installed on the aircraft.
1). Pump type:
Single pump: water pump electrical connection P1
Double pump: Water pump electrical connection P1 and P2