AB point record setting: Open the assistant software and enter
"Advanced"-> "Plant protection function"-> "AB record", select the
channel in the drop-down box of the mapping channel on the right.
AB execution setting: K ++ supports two ways for AB execution
setting.
Method one (recommended): Open the assistant software and enter "Basic"->
"Remote Controller Settings"-> "Airplane Mode", and select one of the three
drop-down boxes to set to AB execution.
Method 2: Open the assistant software and enter "Advanced"-> "Plant protection
function"-> "AB execution", and select the channel in the drop-down box of the
mapping channel on the right.
It cannot be unlocked in this mode.
2). Operating instructions
Step 1: Clear AB point
Quickly flip the AB point recording channel back and forth, and the LED lights flash
red, green, and yellow alternately and fast to clear it. If you want to fly to the point of
drug withdrawal, skip this step.
Step 2: Switch to AB operation mode
The remote control switches the 5-channel mode switch to the AB operation mode
position.
Step 3: Record point A
Hover in AB operation mode and dial the AB record control lever to the second
gear. After the recording is completed, the LED flashes yellow for 2 seconds.
Step 4: Record point B
Hover in AB operation mode and dial the AB record control lever to the third
gear. After the recording is completed, the LED flashes green for 2 seconds.
Step 5: Choose a direction
Select the direction by turning the roll lever. Move the roll lever to the left to move
to the left, and move the roll lever to the right to move to the right. The premise of
performing this step is that the last recorded AB point has been cleared, otherwise
the step will be skipped and continued according to the last AB job.