EasyManua.ls Logo

Jntech JNP22KH-V5 - Page 70

Jntech JNP22KH-V5
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
70
debugging.
DebugMode
This value represents the operating mode of
the inverter:
=0, indicating that the inverter is in vector mode
+ reliable type
=1, indicating that the inverter is in VF mode +
reliable type
=2, indicating that the inverter is in vector mode
+ economic mode
=3, indicating that the inverter is in VF mode +
economic mode
=4, indicating that the inverter is in RC mode
=5, indicating that the inverter is in the mode of
distributed detection of motor parameters
=6, indicating that the inverter is in the mode of
continuously detecting motor parameters
=8, indicates that the inverter is in theoretical
calculation of PI parameters
=9, indicating that the inverter is in group
control mode
=10, indicating that the inverter is in the ac
current calibration mode
VC-Sel
=0 full-order model;
=1 voltage model;
=2 Improved voltage model;
=3 Improved full-order model;
FL-Limit
The flux limit of the motor.

Table of Contents