Firmware Version 3.5 Factory Field Installation
24-10025-199 Rev. –
16
RESTORING THE CONTROLLER’S CONFIGURATION SETTINGS
Use Tera Term Pro to configure the CK721-A controller for operation. You
must configure each controller before connecting it to the Johnson Controls
Security Management System (SMS).
To prepare a CK721-A controller for operation:
1. Enter the IP address of the CK721-A.
2. Enter the netmask of the CK721-A.
3. Enter the IP address of the host.
4. Configure the Download Port number, the Upload Port number, and
the Priority Port number to match those defined at the host.
Once the IP addresses are assigned at the controller, they
cannot be changed from the P2000 software.
5. If needed, modify the encryption information
6. If needed, modify the network polling rate.
7. If needed, modify the route information.
8. If needed, modify the network polling delay.
Once each controller has been configured for operation, reconnect each
controller to the P2000 host. For details on preparing a CK721-A controller for
operation and connecting to the host, refer to the CK721-A Network Controller
Installation and Operation Manual.