Operating manual
Version 1.10
Unisab III Control
en

Other manuals for Johnson Controls Unisab III

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls Unisab III and is the answer not in the manual?

Johnson Controls Unisab III Specifications

General IconGeneral
CategoryControl Systems
ManufacturerJohnson Controls
Enclosure RatingIP20
Power Consumption5 VA
Operating Temperature0 to 50°C (32 to 122°F)
Input Voltage24 VAC/DC

Summary

Preface

Emergency stop

Describes how to activate and deactivate the emergency stop function.

Technical Data

1. Operating Unisab III Control

1.1. Introduction

Overview of the Unisab III control system's purpose, function, and application.

1.1.2 Display

Details the Unisab III display layout, including top bar, content, info, and F-key areas.

1.1.3 Front panel

Explains the three sections of the Unisab III front panel: control, menu, and F-key.

1.1.4 Menu structure

Describes the menu system structure for compressor operation, set values, and configuration.

1.1.5 Session

Covers user login, password levels, and session management within the Unisab III.

User interface settings

Details options for customizing the user interface, including idle timer and auto expansion.

Languages and Contrast Adjustment

Explains how to change the display language and adjust screen contrast for optimal visibility.

1.1.6 Changing set values

Provides a step-by-step guide on modifying alarm limits, set points, and timer values.

1.1.7 Favourites

Describes the use of predefined and user-definable favourite screens for daily compressor operation.

1.1.8 Manual and auto operation

Explains how to select and operate the compressor in manual, auto, or remote control modes.

Manual operation actions

Details manual capacity loading/unloading, starting, and stopping the compressor.

1.1.9 Shutdown and alarm acknowledgement

Covers acknowledging compressor shutdowns and alarms, and their indication methods.

1.1.10 Factory settings

Explains how to reset the Unisab III to its factory default settings for various parameters.

1.1.11 Set values

Lists different set values for pressures, temperatures, and timers with min, max, and factory settings.

1.2. Pressure levels and temperatures

1.2.1 Measured and calculated pressure levels - screws

Provides min, max, and factory values for pressure measurements in screw compressors.

1.2.2 Measured and calculated temperatures - screws

Lists min, max, and factory values for temperature measurements in screw compressors.

1.2.3 Measured and calculated pressure levels - recips.

Details min, max, and factory values for pressure measurements in reciprocating compressors.

1.2.4 Measured and calculated temperatures - recips.

Shows min, max, and factory values for temperature measurements in reciprocating compressors.

1.2.5 Measured/calculated pressure levels/temp. - HPO/HPC

Presents pressure and temperature data for HPO/HPC compressors with min, max, and factory settings.

1.2.6 Notes

Contains explanatory notes related to pressure and temperature measurements and their associated limits.

1.2.7 Oil pressure calculations

Explains the methods for calculating oil pressure based on different compressor types and diagrams.

1.3. Shutdowns and alarms with identification numbers for screw compressors

1.3.1 Shutdowns and alarms for screw compressors

Lists all possible shutdowns and alarms for screw compressors with their Danbuss and Profibus/Modbus IDs.

1.4. Shutdowns and alarms with identification numbers for reciprocating compressors

1.4.1 Shutdowns and alarms for reciprocating compressors

Details shutdowns and alarms for reciprocating compressors, including their identification numbers.

1.5. Timers

1.5.1 Timer values - screw compressors

Presents timer values for screw compressors, including factory, low, high, and adjustable settings.

1.5.2 Timer values - reciprocating compressors

Lists timer values for reciprocating compressors with factory, low, high, and adjustable parameters.

1.6. Spare parts for Unisab III

Spare parts set

Lists essential spare parts kits for the Unisab III control system, including part numbers.

Position transmitter

Provides part numbers for various position transmitters compatible with different SAB compressor models.

Unisab III Diagnosis

Shutdowns Measured Values History

Displays historical records of measured values related to compressor shutdowns.

Shutdowns Input/Output State History

Shows historical data for digital input and output states during compressor shutdowns.

Diagnosis Hardware Digital I/O

Details the digital inputs and outputs within the Unisab III's hardware for diagnostic purposes.