3.4.2 TROUBLESHOOTING –SPEED DOES NOT DISPLAY---CONTINUED
2. Remove the side cover and check to see if the sensor wire is firmly connected.
3. Check to see if one corner of the sensor is aligned with the magnet and that the distance is less than
5mm.
3.4.3 TROUBLESHOOTING –NO HAND PULSE RESPONSE
Symptom:
The console does not display the heart rate during exercise.
Solution:
a. The user must hold one grip sensor in each hand.
b. Maintain moderate pressure while holding onto the heart rate handlebars.
c. Check to see if the wires are firmly connected to the sensor.
3.4.4 TROUBLESHOOTING – SPEAKER/AUDIO ISSUES
Symptom:
The speaker or headphones have no sound output.
Possible Reason:
a. The speaker wire is not firmly connected to the UCB.
b. The audio short circuit terminal is missing.
c. The software is obsolete.
d. The head phone wire or board is defective.
Solution:
a. Confirm whether the speaker wire is firmly connected to the UCB.
b. If firmly connected, make sure that the audio output short-circuit terminal is present and tight.
c. Update the console software (see Section 2.4).
d. If the speakers have sound output, but the headphones do not, replace the headphone wire. If problems
persist, replace the headphone board.