Chapter 2 Names and Functions of System Components
29
The blink patterns change with alarm stages.
Blink pattern at visual indication
1 s turn on - 1 s turn off
Blink pattern at first stage bridge audible alarm
1 time blink/1 s - 1 s turn off
200ms 200ms
Turn on Turn on
Blink pattern at second stage remote audible alarm
2 times blink /1 s - 1 s turn off
200ms 200ms 200ms 200ms
Turn on Turn on Turn on Turn on
200ms
Off
Blink patterns at third remote audible alarm
200 ms turn on - 200 ms turn off repeat