41
5) When press , it returns to the countdown screen and start operation with the changed
setting.
3.4.3 Changing third stage remote audible alarm transfer time
1) Call the SET VALUE screen in according to the procedure of the section “3.4.1 Call of menu
mode screen”.
2) Select [ALARM TIME], and then press .
[ALARM TIME] screen is displayed.
3) Select [3RD STAGE] with , and then press .
4) Change the 3rd stage remote audible alarm transfer delay time.
Select your required transfer delay time with , and then press .
When this setting change is canceled, press .
A transfer delay time can be set to 0 s, 90 s, 100 s, ---, 180 s.
When setting to 0 second, the 2nd stage remote audible alarm and the 3rd stage remote
audible alarm are outputted simultaneously.
5) Press .
When this setting change is canceled, press .
6) When press , it returns to the countdown screen and start operation with the changed
setting.
At passenger ship, do not set to 0 second.