7
GENERAL USE & WARNING SYSTEM:
• PowerCap
®
Innity
®
will deliver a minimum 160L/min of ltered air to the user for upwards of 8 hours through a fresh pair of lters.
• The user may notice changes in motor tone associated with movement, this is a normal operational sound linked to motor construction.
• The array of LEDs at the top of the eld of vision is a Head-Up Display (HUD) informing the user of PowerCap
®
Innity
®
’s status. See
warning scenario table.
• As the battery approaches low remaining charge, the green light will be joined by a ashing red light to inform the user of having
approximately 20 minutes to withdraw from the hazard area to replace/recharge the battery.
• As the battery approaches a fully discharged state, the green light will extinguish and the ashing red light will be joined by a two-tone
buzzer. The user should withdraw from the hazard zone immediately to replace/recharge the battery pack.
• Do not use or store PowerCap
®
Innity
®
at temperatures below +5°C as the battery performance can be affected.
• When the green light is replaced by a blue ashing light and a pulsed buzzer tone, the system is no longer able to deliver sufcient airow
as the lters have become blocked. The user should withdraw from the hazard zone immediately to check and/or replace both lters.
• PowerCap
®
Innity
®
is rated as IP54 for protection against water and dust ingress. The unit can be used in dusty environments and
inclement weather conditions. It should not be immersed in water.
USING POWERCAP
®
INFINITY
®
:
• Operating temperature should be between +5°C and +40°C and relative humidity not greater than 75%.
• PowerCap
®
Innity
®
offers respiratory protection against spores, bres, fumes (very ne metallic droplets/particles) and dusts.
• The visor offers protection against medium energy impacts, short circuit electric arcs, molten metals and hot solids to EN166.
• The EVO5
®
helmet offers protection against falling objects to EN397.