JUDO PROFI-PLUS 17
Faults
5.5 Stoppages
ATTENTION
(see chapter “Safety information and dan-
gers due to non-compliance”)
If a filter has to be removed from the flange
or unscrewed, the chapter "Intended use"
must always be observed!
– Protect the flange surfaces from dam-
age! Damaged flanged surfaces cannot
close tight. As a result, escaping water
can damage the building and installa-
tions.
– Ensure that no dirt can get into the filter!
This dirt can get into contact with and be
discharged into the drinking water when
the filter is switched back on. The health
of people who drink dirty water is at risk.
– Store the filter in frost-free conditions!
Frost can cause any water contained in
the filter voids to freeze and thus cause
mechanical damage to the filter so that it
leaks at operating pressure or can burst.
Leaking water can cause major damage
to the building. In addition, people near
the filter can be injured by breaking off fil-
ter parts.
– When restarting the filter, follow the in-
structions for a new filter.
6. Faults
In order to ensure unit safety and leak
tightness, only approved persons may
open the units and replace parts subject
to water pressure.
Help with faults:
Fault Cause Remedy
Backwashing water contin-
ues running!
Flushing valve not fully
closed.
Repeat the backwashing and
then turn the handwheel until
it locks into place!
Dirt in the flushing valve.
Water flow rate falls! Screen is blocked. Carry out backwashing.
Leaks in the filter! Inform the fitter or nearest
customer service centre. (The
filter cover must be replaced
immediately.)
Filter cover becomes turbid! Filter has been exposed to
high temperatures or sol-
vents.
Hairline cracks on the filter
hood!
Note electronics beeps!
(JPF
+
¾" – 1¼")
Backwashing is due. Carry out backwashing. Keep
the
RESET-key pressed for at
least 3 seconds.
The note electronics does
not beep when the
RESET-
key is pressed!
(JPF
+
¾" – 1¼")
The battery is used up. Replace the batteries with
new ones. Return used bat-
teries to the collection cen-
tres.