– 80 –
(4) Lubrication mechanism configuration and adjustments (DDL-9000B-SS, SH, MA, MS)
Fixed to the arm
Lubrication mechanism configuration of the DDL-9000B-SS, SH, MA, MS
Standard Adjustment
Fixed to the bed
This part is not used in
the DDL-9000B-MA and MS.
The float case guide
is
entered in the slide guide
of the peep window.
Float case cap
(appropriative to DDL-9000B-MA, MS)