Indication Level Functions Setting range Remarks
U Max sewing speed 400~3000rpm 3000 To be set at 2700 for the
(Setting possible in the unit of 100rpm)
LK-1900AW and LK-1903A.
U Sewing speed for the first stitch 400~1500rpm 1500
(with needle thread clamp)
(Setting possible in the unit of 100rpm)
U Sewing speed for the second stitch 400~3000rpm 3000
(with needle thread clamp)
(Setting possible in the unit of 100rpm)
U Sewing speed for the third stitchj 400~3000rpm 3000
(with needle thread clamp)
(Setting possible in the unit of 100rpm)
U Sewing speed for the 4th stitchj 400~3000rpm 3000
(with needle thread clamp)
(Setting possible in the unit of 100rpm)
U Sewing speed for the 5th stitch 400~3000rpm 3000
(with needle thread clamp)
(Setting possible in the unit of 100rpm)
U Thread tension for the first stitch 0~200 200
(with needle thread clamp)
U Thread tension at the time of 0~200 0
thread trimming
U Changeover timing of thread ten- –6~4 0
When the setting value isincreased,
op-
sion at the time of thread trimming (~–1:32°, 0:28°, 1:24°~)
eration becomes faster in the unit of 4°.
U Sewing speed for the first stitch 400~1500rpm 400
(with needle thread clamp)
(Setting possible in the unit of 100rpm)
U Sewing speed for the second stitch 400~3000rpm 900
(with needle thread clamp)
(Setting possible in the unit of 100rpm)
U Sewing speed for the third stitch 400~3000rpm 3000
(with needle thread clamp)
(Setting possible in the unit of 100rpm)
U Sewing speed for the 4th stitch 400~3000rpm 3000
(with needle thread clamp)
(Setting possible in the unit of 100rpm)
U Sewing speed for the 5th stitch 400~3000rpm 3000
(with needle thread clamp)
(Setting possible in the unit of 100rpm)
U Thread tension for the first stitch 0~200 0
(with needle thread clamp)
U Changeover timing of thread ten- –5~2 0
When the setting value is increased,
sion at the sewing start (~ –1: 64°, 0: 60°, 1: 56°~) operation becomes faster in the
(with needle thread clamp) unit of 4°.
U
Display of Pattern No., XY enlargement/
0: Operative 0
In case of setting 1, use of M key is
reduction scale rate, and max. 1: Inoperative
prohibited as well. When changing
speed limits; change enabled/disabled memory switch, pressing M key, turn
ON the power switch.
(Standard operation panel)
U Counter operation 0: Production counter (addition) 0 (Standard operation panel)
1: Bobbin thread counter
(subtraction)
U Selection of pedal 0: Standard pedal 0
1: Standard pedal
(2-step stroke)
2: Optional pedal
3: Optional pedal
(2-step stroke)
U Selection of pedal 0: Standard pedal 0
1: Optional pedal
State when
delivered