58
No. Function
Setting range
State when delivered
Remarks
U025
Optional pedal 2 operation
OFF when depressing pedal again
OFF when detaching from pedal
-
U026
Height of work clamp foot at the time of 2-step
stroke
50 to 90 70 Height is lowered
when the set value
is increased.
U030
Selection of base point of pattern enlargement/reduction
: Origin : Sewing start point
-
U031
Sewing machine operation can be stopped with panel key (clear key).
: Ineffective :
Panel RESET key
: External switch
-
U032
Buzzer sound can be prohibited.
:
Without buzzer sound : Panel operation sound
: Panel operation sound + error sound
-
U033
Number of stitches that needle thread clamp
releases is set.
1 to 20
stitches
2
U034
Clamping timing of needle thread clamp can be
delayed.
10 to 4 4
Timing is delayed in
“-” direction.
U035
Needle thread clamp control can be prohibited.
: Normal : Prohibited
-
Misapplication of
panel is protected.
For LK-1903BN, set
to " ".
U036
Feed timing is selected.
When stitches are not well-tightened, set the value in
“–” direction.
− 8 to 16 12
Setting on exces-
sive “–” side may
cause needle break-
age. Be careful
when sewing heavy-
weight material.
U037
State of work clamp foot after completion of sewing can be selected.
: Work clamp foot goes up after moving at the sewing start
:
Work clamp foot goes up immediately after the end of sewing.
: Work clamp foot goes up by pedal operation after moving
at the sewing start.
-
For LK-1903BN/
BR35, set to " ".
U039
Execution of origin retrieval every time after completion of
sewing can be performed.
(Except cycle stitching)
: Without origin retrieval : With origin retrieval
-
U040
Setting of origin retrieval in cycle stitching can be set.
: Without origin retrieval
: Every time 1 pattern is completed
: Every time 1 cycle is completed
-
U041
State of work clamp foot when machine stopped by temporary
stop command can be selected.
:
Work clamp foot goes up.
: Work clamp foot goes up with work clamp foot switch.
: Lift of work clamp foot is prohibited.
-