59
No. Function
Setting range
State when delivered
Remarks
U042
Needle bar stop position is set.
: UP position : Upper dead point
-
Needle bar rotates
in the reverse direc-
tion after the UP po-
sition stop and stops
when upper dead
point stop is set.
U046
Thread trimming can be prohibited.
: Normal : Thread trimming prohibited
-
U048
Route of origin return by means of clear key can be selected.
: Straight line return :
Reverse return of pattern
- This function is
used when straight
line return from the
midway of pattern
to the start of sew-
ing is not possible.
U049
Bobbin winding speed can be set.
800 to 2000 1600
Max. speed limita-
tion has priority.
U050
Operation timing of material closing is selected. LK-1901BN
only
Output prohibited
: Operation when work clamp foot comes down.
: Operation at the time of start
- For the machines
other than LK-
1901BN, this func-
tion is not indicat-
ed.
U051
Wiper operation method can be selected.
:
Without wiper at the time of thread trimming on the way
: With wiper at the time of thread trimming on the way
󰴤
: With wiper at the time of thread trimming on the way
󰴥
: Magnet wiper
-
󰴤
: Without return
of the last wiper
󰴥
: With return of
the last wiper
U055
Effective/ineffective of tie stitching for button sewing can be
selected.
: Tie stitching effective : Tie stitching ineffective
-
.
U064
The dimension input increment can be selected.
: In percentage (%) : In dimension
-
U065
Y origin shift method can be selected.
: Standard
: Offset by
5 mm (for 1904 work clamp)
-
U069
Common/individual of the 2-step stroke height is selected.
: Common
: Individual (the height can be set with respect to each direct pattern)
-
U070
Display/hide of the travel of the last stitch can be set.
: Hide : Display
-
U074
The fan operation can be set.
: Energy saving mode : Constantly operates
-
U075
With/without air pressure detection
: Without : With
* This memory switch is displayed only for the LK-1900BBN, LK-
1903BBN.
-