– 8 –
(6) Needle-to-hook timing
WARNING :
Turn OFF the power before starting the work so as to prevent accidents caused by abrupt start of the
sewing machine.
Standard adjustment
1) Height of the needle bar
2) Needle-to-blade point of hook timing
3) Adjusting the hook needle guard
8
A
6
7
B
2
3
1
4
5
9
C
!0
6
!1
6
!0
!2
D
E
d
e
Model
Dimension A
(mm)
Dimension B
(mm)
Dimension C
(mm)
LU-2810
2.3 ± 0.2 1.5 ± 0.2 0.05 to 0.2
LU-2810-7
[Conditions]
Feed amount : 0 mm
Needl bar rises from the lowest dead point of its stroke.