2) Alternate vertical change base
1. Remove top cover.
2. Remove two return springs
4
of alternate vertical change base.
3. Loosen setscrews
1
of felt clamp to remove felt clamp
2
.
4. Apply JUKI grease A to felt
3
.
5. Apply JUKI grease A to sliding surfaces of alternate vertical change base and feed conversion link.
6. Set felt clamp
2
to alternate vertical change base, and x it with setscrews
1
of felt clamp.
7. Attach two return springs
4
of alternate vertical change base.
8. Attach top cover.
4
1
2
3
3) Horizontal feed change base
1. Remove rear cover.
2. Loosen setscrews
1
of felt clamp to remove felt clamp
2
.
3. Apply JUKI grease A to felt
3
.
4. Apply JUKI grease A to sliding surfaces of horizontal feed change base and feed conversion link.
5. Set felt clamp
2
to horizontal feed change base, and x it with setscrews
1
of felt clamp.
6. Attach rear cover.
1
2
3
海外講習会用121122LU-2810(-7)EM