EasyManua.ls Logo

JUKI SC-920 - Replacing the fuse

JUKI SC-920
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44 –
2. Replacing the fuse
(Caution) The illustration below shows the PWR-T PCB. The type of PCB differs by destination.
1) Remove all the cables
which are connected to
the control box.
2) Remove the connecting
rod.
3) Remove the control box
from the table stand.
4) Holding the glass section
of fuse
, remove the
fuse.
(Caution) There is a risk of electrical shock when removing the fuse. Be sure to remove the fuse after LED
has totally gone out.
5) Be sure to use a fuse with the designated capacity.
: 3.15 A/250 V Time-lag fuse
(Power circuit protective fuse)
Part number: KF000000080
6) Install the control box on the table stand. (Refer to II-2. Installing to the table” p.3.)
7) Connect all the cables to the control box. (Refer to II-4. Connecting the cords” p.5.)
8) Fit the connecting rod back in place. (Refer to II-5. Attaching the connecting rod” p.11.)
3) Loosen setscrew
in cover
. Open cover
.
4) To close cover
, re-tighten setscrew
while pay-
ing attention to the orientation of cable clip band
mounted on the side face of the box.

Other manuals for JUKI SC-920