Battery parameters
No. Function Setting
range
Standard
setting
Comments
1377
Battery type
2
0 - 9 1 0 = PzS (wet cell battery)
1 = EPzS (high
performance)
2 = EPzV (maintenance-
free gel/dry battery)
3 = US "Flat Plate" battery
4 = US "Pallet Pro" battery
5 = US "Tubular Plate"
battery
8 = Lithium ion battery (o)
9 = XFC (dry-cell battery)
1389 Discharge
monitor
0 /1 1 0 = Not active
1 = Active
NOTICE
Battery damage
The battery, charger (charge characteristics) and battery parameters must match
each other, otherwise damage may result.
2)
The setting for maintenance-free gel/dry batteries or special batteries, for example XFC, is shown in the display unit.
127