5.1 Truck does not start
Possible Cause Remedy
Battery connector not inserted Check the battery connector
and insert if necessary
Emergency Disconnect switch pressed Release the Emergency Disconnect
switch, see page 64
Key switch set to O Set the key switch to “I”
Deadman switch not pressed Press deadman switch
Battery charge too low Check battery charge,
Charge battery if necessary, see
page 38
Faulty fuse Check fuses see page 120
Incorrect ISM access module
transponder used
Use correct transponder
Incorrect CANCode PIN entered Enter correct PIN, see page 86
5.2 Load cannot be lifted
Possible Cause Remedy
Truck not operational Carry out all measures listed under
“Truck does not start”.
Hydraulic oil level too low Checking the hydraulic oil level
Battery discharge monitor has switched
off
Charge the battery
Faulty fuse Check fuses
Excessive load Note maximum capacity, see data plate.
Switch in mast implausible (E-2124) Emergency recovery (travel at max. 1.5
km/h and lowering possible when truck is
in rider mode). Contact the
manufacturer's service department.
77
04.19 en-GB

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jungheinrich ESE 220 and is the answer not in the manual?

Jungheinrich ESE 220 Specifications

General IconGeneral
BrandJungheinrich
ModelESE 220
CategoryTrucks
LanguageEnglish

Related product manuals