2. Place the grounding lug aached to the grounding cable over the protecve earthing terminal on the
rear panel.
3. Secure the grounding lug to the protecve earthing terminal using the 10-32 x .25-in. screws with
#10 split-lock washers.
4. Dress the grounding cable. Be sure that the cable doesn’t block access to or touch other device
components, and that it doesn’t drape where people could trip over it.
Connect the Power Cord and Power On the Switch
For informaon about the supported AC power cord specicaons, see Table 44 on page 92.
To connect the power cord, do the following:
1. Ensure that the power supply is fully inserted in the rear panel of the switch.
2. On the rear panel, connect the retainer strip and power cord to the AC power socket:
a. Push the end of the retainer strip into the hole next to the AC power socket unl it snaps into
place. Ensure that the loop in the retainer strip points upward.
b. Press the small tab on the retainer strip to loosen the loop.