Table 67: EX4400 Environmental Tolerances
Altude Relave Humidity Temperature Seismic
No performance
degradaon up to
6000 feet at
104° F
(1828.8 meters at
40° C)
Normal operaon
ensured in relave
humidity range of
5% through 90%,
noncondensing
Normal operaon ensured in temperature
range of 32° F through 113° F (0° C through
45° C)
Nonoperang storage temperature in
shipping container: –40° F through 158° F (–
40° C through 70° C)
Tested for Zone 4
earthquake
according to
NEBS GR-63-
CORE, Issue 5.
NOTE
: Install the EX4400 only in restricted-access areas, such as dedicated equipment rooms
and equipment closets, in accordance with Arcles 110-16, 110-17, and 110-18 of the Naonal
Electrical Code, ANSI/NFPA 70. Only skilled and instructed persons must access the device.
General Site Guidelines
Ecient device operaon requires proper site planning and maintenance. It also requires proper layout
of the equipment, rack or cabinet, and wiring closet.
To plan and create an acceptable operang environment for your device and prevent environmentally
caused equipment failures:
Keep the area around the chassis free from dust and conducve material, such as metal akes.
Follow the prescribed airow guidelines to ensure that the cooling system funcons properly. Ensure
that exhaust from other equipment does not blow into the intake vents of the device.
Follow the prescribed electrostac discharge (ESD) prevenon procedures to prevent damaging the
equipment. Stac discharge can cause components to fail completely or intermiently over me.
Install the device in a secure area, so that only authorized personnel can access the device.