Ch 8 Barcode Scanner 85
Mesas. Now all the Mesas can load from Prole 1 to get back to
this restore point.
4 – When I read a barcode, the data returned is not correct.
Reason/Solution: Ensure that the congurations are set up
correctly so you are given the information you need. For
example, to read a Code 32 barcode, on the 1D Code Type tab,
ensure that Code 39 is selected. Select Options, and on the Code
39 tab ensure that Convert Code 39 to Code 32 is selected.
5 – I don’t know what type of barcode I am trying to scan.
Reason/Solution: Enable all the barcode types on the 1D Code
Types, Composite/Postal Code Types, and 2D Code Types tabs (some
types are mutually exclusive). Go to the Test tab. Scan the
barcode and the Code Type window shows the type of barcode
scanned. When you are nished, go back and deselect barcode
types you are not using.
6 – My TLC-39 Composite barcode will not scan.
Reason/Solution: On the 1D Code Types tab ensure that Code 39 is
checked. Also select Options, then the Code 39 tab and ensure
that Convert Code 39 to Code 32 is unchecked.
7 – My UPC barcode will not scan.
Reason/Solution: On the 1D Code Types tab ensure that barcode
types UPC-A, UPC-E and UPC-E1 are checked. If composites
codes are also enabled on the Composite/Postal Code Types
tab and you still want to allow a UPC 1D to scan, select
Autodiscriminate from the drop down list. Also go to the 1D
Code Types tab, select Options, then the tabs for UPC/EAN-1
and UPC/EAN-2. Make sure the seings are correct for your
application.
8 – My Code 39 Full ASCII barcode will not scan.
Reason/Solution: On the 1D Code Type tab, select Options, then
the Code 39 tab. Ensure that the lengths are set to the fullest
range.