PTX10000 Field-Replaceable Units
Field-replaceable units (FRUs) are router components that you can replace at your site. The router uses
these types of FRUs:
•
Hot-insertable and hot-removable—You can remove and replace these components without powering
off the router or disrupting the routing function.
•
Hot-pluggable—You can remove and replace these components without powering off the router, but
the routing function is interrupted until you replace the component.
Table 6 on page 40 lists the FRUs and their types for the PTX10000 routers.
Table 78: FRUs in an PTX10000 Router
TypeFRU
Hot-insertable and hot-removable.Power supplies
Hot-insertable and hot-removable.Fan tray
Hot-insertable and hot-removable.Fan tray controller
Redundant configuration:
•
Master RCB is hot-pluggable.
•
Backup RCB is hot-insertable and hot-removable.
Base configuration:
•
Removal of the RCB causes the router to shut down. You can install a
replacement RCB in the second slot. The system restarts to elect a master and
backup. If necessary, you can switch the master and backup using the request
chassis routing-engine master switch command.
See “PTX10008 Components and Configurations” on page 35 and PTX10016
Components and Configurations.
Routing and Control Board (RCB)
SIBs are hot-insertable and hot-removable. We recommend that you take SIBs
offline before removing them to avoid traffic loss while the router fabric is being
reconfigured. For example:
user@router> request chassis sib (offline | online) slot slot-number offline
Switch Interface Boards (SIBs)