EasyManua.ls Logo

Juniper PTX10008 - Page 55

Juniper PTX10008
479 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 10: Fan Tray LEDs on a PTX10000 Router (continued)
DescriptionStateColorName
The fan tray controller is online and is
operating normally.
On steadilyGreenFan tray controller status
The beacon feature is enabled. This feature
is enabled using the request chassis
beacon command.
BlinkingGreen
An error has been detected in the fan tray
controller. Replace the fan tray controller
as soon as possible. The fan tray controller
is located behind the fan tray above the
SIBs. To maintain proper airflow through
the chassis, leave the fan tray installed in
the chassis until you are ready to replace
the fan tray controller.
BlinkingYellow
The fan tray controller is not receiving
power.
OffNone
The left-most SIB in the chassis is online.On steadilyGreenSIB 0 status
The beacon feature is enabled. This feature
is enabled using the request chassis
beacon command.
BlinkingGreen
An error has been detected in SIB 0.
Replace the SIB as soon as possible. The
SIB is located behind the left fan tray and
is the left-most SIB in the chassis. To
maintain proper airflow through the
chassis, leave the fan tray installed in the
chassis until you are ready to replace the
SIB.
BlinkingYellow
The SIB is offline.OffNone
56

Table of Contents

Other manuals for Juniper PTX10008

Related product manuals