(No.YA683<Rev.001>)1-15
4.7 HOW TO VERIFY THE PROTECT MODE
The Sub CPU always surveys the power supply circuit. If the ab-
normal voltage is detected on the power supply circuit, a voltage
is not supplied.
Perform the following procedures for confirmation.
(1) Enter the service mode.
(2)
The following screen appears.
Indication of Safety
4.8 HOW TO INITIALIZE THE LCD TELEVISION
(1) Turn the power on.
(2) To enter the service mode.
• To cancel the service mode, press [POWER] key on the
remote control unit.
(3) Press [AV] key on the service remote control unit to initial-
ize the LCD television.
(4) "INITIALIZED" will appear in the upper right of the screen.
"INITIALIZED" color will change to green from red when
initializing is complete.
INDICATION DESCRIPTION
Safety_Non The power supply circuit is normal.
Safety1 The power supply circuit is abnormal.
(Protect1)
Safety2 The reduced voltage detection circuit is
abnormal. (Protect2)
Safety3 The inverter circuit is abnormal. (Protect3)
Code :
Boot :
System :
SubCPU :
Pic Code :
Picture :
Panel :
Other :
Safety :
HDMI1 Block0 :
Block1 :
HDMI2 Block1 :
**********-***
**** * ***
**** * ***
****
**-***-**-****-***
****
***
**
Safety_Non
**
**
**
SPAIN
"
*
" differs depending on the models.
Display protection mode