JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500 267
5.7 Expansion Module MAC00-FD4
5.7.26 Hardware I/O setup
The drawing below shows the SW3 Dip-switch location. The various settings of SW3 is
shown on the previous page.
Switch description:
The factory default setting is:
SW3 Description Function Signal name
Dip 1 RS232 interface - transmit output ON = Enable Tx
Dip 2
Dip 3
I/O terminal A
DIP2=ON and DIP3=OFF:
AIN (Analogue input)
IOA
Dip 2
Dip 3
I/O terminal A
DIP2=OFF and DIP3=ON:
O2 (output 2)
IOA
Dip 4 I/O terminal B
DIP4=ON: Output 1
DIP4=OFF: Input 1
IOB
Dip 5 I/O terminal C
DIP5=ON: O1 output
DIP5=OFF: PL (positive limit input)
IOC
Dip 6 I/O terminal D
DIP6=ON: O+ (Output supply)
DIP6=OFF: NL (Negative limit input)
IOD
SW3 ON OFF Function
Dip 1 X RS232 interface Enable
Dip 2
Dip 3
X
X
O2 (output 2)
Dip 4 X Input 1
Dip 5 X O1 output
Dip 6 X 0+ (output supply)