E. PROGRAM THE LOCK FOR
TAMPER TIME PARAMETERS
You can set a Tamper Time Wrong Tries parameter referring to the number of
times the wrong code can be entered before the lock goes into Tamper
Shutdown Mode.
For example, if you program the lock to accept three wrong tries, the lock will
tolerate three wrong entries, staying locked but providing visual feedback (see
visual message chart in rear section). After that, it will go into a Tamper
Shutdown Mode and remain locked until the end of the Tamper Shutdown Time
period - the length of that period is configured in Steps 1a through 1 c below.
Required User Level: Master, Manager
E-1 Set the tamper time for the period of time during which the keypad will
remain inaccessible after the specified number of wrong Access Codes
are entered
a. Put the lock into Pushbutton Programming Mode.
b. Enter the code as follows - 006#TT# (TT is seconds - 00 to 90 seconds).
c. Example of Complete Entry: 006#30#. (for 30 seconds)
E-2 Enter the code as follows: 007 #TT# (TT is number of wrong entries -
03 to 09), let’s use 03 for example.
a. Example of Complete Entry: 007#03#.
b. Enter another # to indicate the end of programming.
c. The lock will stay locked after three wrong entries for the length of
time you select in the steps below, even if a valid code (including the
Master or a Manager Code) is entered after the three wrong codes.
Only the mechanical key override will open the lock during the
lockout period.
d. Enter another # to indicate the end of programming.
In this example, the lock will now remain locked out for 30 seconds after three
wrong Access Codes have been entered. No codes, even valid ones, will work in
the lock until that time period has elapsed. During this tamper shut down peri-
od, the lock will flash the red LED once every 10 seconds
F. PROGRAMMING THE LOCK
FOR KEYPAD BUZZER VOLUME
You might want to adjust the volume of the Keypad Buzzer depending on where
the lock is located - a noisy or quiet area.
Required User Level: Master, Manager
F-1 Put the lock into Pushbutton Programming Mode.
F-2 Enter the code 008#VV# (where VV is a scale of volume from 00 to 03;
00 = off; 01 = Low; 02 = Normal; 03 = High).