7
DEFAULT VALUES OF THE E-PLEX 2000
PROGRAMMABLE PARAMETERS
Parameters Factory Default Values
Lock state Unprogrammed
Passage mode open time limit 9 hours
Passage mode De-Activated
Lockout mode De-Activated
Unlock time 2 seconds
Buzzer volume control Low
Tamper shutdown time 30 seconds
Tamper attempt count 4 attempts
Access code length 4 digits
Master combination 12345678 (8 digits)
Access code None
Code status Activated
CONFIGURING THE LOCK
General Procedure for Pushbutton Programming
1. The pages that follow provide step-by-step instructions for programming the
E-Plex 2000/EPS2000 lock.
2. The general procedure for all programming functions is as follows:
a. Put the lock in Programming Mode by pressing # Master Code #
b. Use the Summary of Commands Table in the appendix section of this guide
to enter the three digit command sequence (Command Type + Function
Code), followed by #.
c. Enter the appropriate numbers as required.
d. Press # to end Programming Mode.
e. Once the lock is in programming mode, multiple command sequences can be
entered without having to repeat the #mastercode#. However, if there is no
activity for 15seconds at the keypad, the lock will automatically exit from
programming mode.