25
Summary of Pushbutton Programming Commands
Name
Activate
Users
De-activate
Users
Diagnostic
Command
300 #
NNN#
3
01 #
NNN#
3
02 #
NNN#
398 #
399 #
P#
400 #
NNN#
401 #
NNN#
402 #
NNN#
498 #
499 #
L#
500 #
123456789*0#
Description of Command
‘Activate User Access Code’
NNN = specific User ID location (001 to 099)
‘
Activate Manager Access Code’
NNN = specific User ID location (001 to 099)
‘
Activate Service User Access Code’
NNN = specific User ID location (001 to 099)
‘Activate all User Codes’ (except Master
and Manager)
‘Activate / De-Activate Passage Mode’
(P = 0 or 1; 0 = disable Passage Mode;
1 = enable Passage Mode)
‘De-Activate User Access Code’
NNN = specific User ID location (001 to 099)
‘De-Activate Manager Access Code’
NNN = specific User ID location (001 to 099)
‘De-Activate Service User Access Code’
NNN = specific User ID location (001 to 099)
‘De-Activate all User Codes’ (except Master
and Manager)
‘Activate / De-Activate Lockout Mode’
(Master User doesn’t affect by Lockout
Mode) (L = 0 or 1; 0 = disable Lockout Mode;
1 = enable Lockout Mode)
‘Manual diagnostic’
Authorization
Master, Mgr
Master
M
aster, Mgr
Master, Mgr
Master, Mgr
Master, Mgr
Master
Master, Mgr
Master, Mgr
Master
Master, Mgr