2.16.1 Power supply specifications
The specifications given relate to the separate power supply for the integrated refrigerated
dryer. Please refer to the specifications given in chapter 6.6 and the electrical diagram in
chapter 13.3 if a common power supply is provided.
Rated power supply: 115V / 1 / 60Hz
CT 4 CT 8
Pre-fuse [A] 15 15
Supply 3xAWG14 3xAWG14
Consumption [A] 3.2 5.1
Tab. 23 Power supply 115V / 1 / 60Hz