Examples of unsuitable fixing points:
■ Pipe sockets
■ Flanges
■ attached components such as cyclone separators, condensate drains or filters
■ Rain protection covers
➤ Please consult with KAESER if you have questions to the appropriate lifting gear.
Precondition The lifting gear complies with local safety regulations.
No pressure should bear on the sides of the enclosure.
Fig. 36 Transporting with a crane
1 Lifting gear
2 Slings
1.
The machine can be damaged by incorrect attachment of the lifting gear!
➤ Do not attach the lifting gear to any of the machine components.
2. Use the lifting gear correctly and lift the machine carefully.
12.5 Disposal
When disposing of a machine, drain out all liquids and remove old filters.
Precondition The machine is decommissioned.
1. Completely drain the cooling oil from the machine.
2. Remove used filters and the oil separator cartridge.
3. Hand the machine over to an authorized disposal expert.
➤ Parts contaminated with cooling oil must be disposed of in accordance with local environ‐
ment protection regulations.
12 Decommissioning, Storage and Transport
12.5 Disposal
9_6917 34 USE
Operator Manual Screw Compressor
AIRTOWER 3C–7.5C Tri-Voltage
89