EasyManua.ls Logo

Kantronics KAM Plus - Configuring Digis for HF;VHF Gateway Operations

Kantronics KAM Plus
81 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
LT
n text
(
n
= 1 – 4) (
text
up to 128 characters) v8.0
Default blank
This command fills the specified Locate Text (LT) buffer with text. n specifies which buffer to use
(1 4). If GPSHEAD is set for this buffer and if the INTFACE command is set to GPS, the buffer
contents will be updated automatically by the GPS data.
LTP
n
dest [via call1[,call2,...]] (
n
= 1 – 4) v8.0
Default GPS/GPS
This command sets the destination callsign and the digipeaters used to transmit the LT strings.
n
specifies which string (1 4). The destination callsign defaults to GPS; however, you may want to
change it to APRS, LOCATE, POSIT or some other destination. Up to 8 digipeater callsigns may be
specified. The values before the / apply to the HF port and the values after the / apply to the VHF
port.
LTRack
n
[LT1] [LT2] [LT3] [LT4] [SYSOP] [TIME]
Default 0
This command allocates memory for a special tracking buffer used to store LT messages.
n
defines
the amount of memory (kBytes) set aside for the LT messages (limited by available RAM). Specify-
ing the LT1 through LT4 parameters determines which message will be stored in the tracking buf-
fer. If SYSOP is specified, only a user with SYSOP privileges may access the tracking buffer, and if
TIME is specified, a time stamp will be appended to the front of the LT message.
The LTRACK buffer is accessed by connecting to the mailbox (MYPBBS) and using the LTRACK
command.
MAll ON | OFF
Default ON/ON
When ON, monitored packets include "connected" packets between other stations. If OFF, other
stations connected packets will not be monitored.
See also: monitor
MARk
n
(
n
= 50 – 4000)
Default 1600
This command sets the mark frequency for HF PACKET operation, and also sets the mark fre-
quency used for non-packet modes when the SHIFT command is set to MODEM. The MARK com-
mand must be set less than the SPACE command.
See also: shift, space
MAXframe
n
(
n
= 1 – 7)
Default 1/4
MAXFRAME sets an upper limit on the number of unacknowledged packets which can be outstand-
ing at any one time. The KAM Plus will send MAXFRAME number of packets in a single transmis-
sion, if they are available.
See also: paclen