Deutsch 5.962-786.0 Rev. 05 (06/13) 25
included in the scope of delivery
possible accessories
- Accessories not available
*temperature sensor PT 100 (6.375-485.0) is set to 68°C in the software.
Optional accessories
VA frame o o o o o o
Steel panels o o o o o o
VA panels o o o o o o
Floor structure o o o o o o
HDC 40/8 HDC40/8H HDC 60/8 HDC60/8H HDC 80/8 HDC80/8H
Performance data
Working pressure MPa
(bar)
16 (160) 16 (160) 16 (160) 16 (160) 16 (160) 16 (160)
Max. excess oper-
ating pressure
(safety valve)
MPa
(bar)
20 (200) 20 (200) 20 (200) 20 (200) 20 (200) 20 (200)
Flow rate l/h (l/min) 4000
(66,6)
4000
(66,6)
6000 (100) 6000 (100) 8000
(133,3)
8000
(133,3)
Water connection
Min. feed volume l/h (l/min) 4000
(66,6)
4000
(66,6)
6000 (100) 6000 (100) 8000
(133,3)
8000
(133,3)
Feed pressure
(min.)
MPa
(bar)
0,15 (1,5) 0,15 (1,5) 0,15 (1,5) 0,15 (1,5) 0,15 (1,5) 0,15 (1,5)
Max. feed pres-
sure
MPa
(bar)
0,6 (6) 0,6 (6) 0,6 (6) 0,6 (6) 0,6 (6) 0,6 (6)
Max. feed temper-
ature
°C 60* 85 60* 85 60* 85
Electrical connection
Current type -- 3~ 3~ 3~ 3~ 3~ 3~
Frequency Hz 50 50 50 50 50 50
Voltage V 400 400 400 400 400 400
Connected load kW 23 24 34 35 45 46
Electrical protec-
tion (slow)
A50508080100100
Maximum allowed
net impedance
Ohm 0.180+j0.1
13
0.180+j0.1
13
0.158+j0.0
99
0.158+j0.0
99
0.138+j0.0
87
0.138+j0.0
87
Power supply mm
2
4x 16 4x 16 4x 35 4x 35 4x 35 4x 35
Dimensions and weights
Length mm 1168 1168 1168 1168 1168 1168
Width mm 768/800 768/800 768/800 768/800 768/800 768/800
Height mm 1424 1424 1881 1881 1881 1881
Weight incl. panel kg 360 380 485 505 560 580
Noise emission