36 Deutsch 5.962-786.0 Rev. 05 (06/13)
Error code 42 is dis-
played
Leakage in the high-pressure
pipeline system.
Locate and seal leakage. Operator
Too many consumer loads
open at the same time.
Close some consumer loads. Operator
Pressure sensor for high pres-
sure defective.
Replace pressure sensor. Customer
Service
Error code 43 is dis-
played
Leakage in the high-pressure
pipeline system.
Locate and seal leakage. Operator
Pressure sensor for high pres-
sure defective.
Replace pressure sensor. Customer
Service
Error code 50 is dis-
played
Pressure sensor for high pres-
sure does not transmit signal.
Check pressure sensor, replace if
required.
Customer
Service
Error code 52 is dis-
played
Temperature sensor does not
transmit signal.
Check temperature sensor, re-
place if required.
Customer
Service
Fault Possible cause Remedy of whom