28
Troubleshooting
Display Value Meaning
Error messages
ERROR calc. drive data 60
Error: During the automatic motor stator resistance mea-
surement.
ERROR output phase fail. 5 Phase loss detection at the output
Error blockade 26
A blockade was recognized.Pn85 Bit 4 is at error, no
auto-reset.
ERROR brake 56
Error can occur with activated brake control (see chapter
brake control) if:
the load during the start is below the min. load level
(Pn43) or the missing of a motor phase was detected.
the load is too high and the hardware current limit is
reached.
ERROR speed ctrl. lim 25 Speed controller limit reached
ERROR ow control 27
The ow control is activated in Pn91. No input and out-
put for valve control is selected in Pn92 and Pn93.
ERROR input error detect 53 Hardware error at start/stop measurement.
ERROR external fault 31
Is triggered, if a digital input is being programmed as
external error input and trips.
ERROR
overspeed
58
The speed is outside the dened limits. (can also occur
on exceeding of the absolute speed referring to EMF =
EMF wrong (servo drives).
ERROR overheat internal 6
Overheating in the interior. Error can only be reset at
"no ERROR overheat int." if the interior temperature has
dropped by at least 3 °C
ERROR load shunt fault 15
Load-shunt relay has not picked up, occurs for a short
time during the switch-on phase, but must automatically
be reset immediately. If the error message remains the
following causes may be applicable:
load-shunt defective
input voltage wrong or too low
high losses in the supply cable
braking resistor wrongly connected or damaged
braking module defective
ERROR power unit 12 Error: General power circuit fault
ERROR motor protection 30 Electronic motor protective relay has tripped.
ERROR max. accelerati-
on
24 Maximum acceleration exceeded
ERROR drive overheat 9
Error: Overtemperature of motor PTC. Error can only be
reset at "no ERROR drive overheat“ if PTC is again low-
resistance. Causes:
Resistance at terminals T1/T2 >1650 Ohm
Motor overloaded
Line breakage to the temperature sensor
further on next side

Other manuals for KEB COMBIVERT G6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT G6 and is the answer not in the manual?

KEB COMBIVERT G6 Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT G6
CategoryDC Drives
LanguageEnglish

Related product manuals