9
CP-Parameter for open-loop operation
2.3 CP-Parameter for open-loop operation
Parameter Range
Resolu-
tion
Default Unit
Flag
based
on
CP00 Password input 0…9999 1 - - - Ud01
CP01 Actual value display -400…400 0,0125 0 Hz R ru07
CP02 Set frequency display -400…400 0,0125 0 Hz R ru01
CP03 Inverter state 0…255 1 0 - R ru00
CP04 Apparent current 0…6553,5 0,1 0 A R ru15
CP05 Apparent current peak value 0…6553,5 0,1 0 A R ru16
CP06 Actual utilization 0…400 1 0 % R ru13
CP07 Actual DC voltage 0…1000 1 0 V R ru18
CP08 DC link voltage peak value 0…1000 1 0 V R ru19
CP09 Output voltage 0…778 1 0 V R ru20
CP10 min. reference forward 0…400 0,0125 0 Hz - oP06
CP11 max. reference 0…400 0,0125 70 Hz - oP10
CP12 acc. time forward 0,00…300,00 0,01 5 s - oP28
CP13 dec. time forward (-1=CP12) -0,01…300,00 0,01 5 s - oP30
CP14 S-curve time acc. 0,00…5,00 0,01 0 s - oP32
CP15 Boost 0,0…25,5 0,1 LTK % - uF01
CP16 Rated frequency 0…400 0,0125 50 Hz - uF00
CP17 Voltage stabilization 0…649 1 off V E uF09
CP18 Switching frequency 0…LTK 1 LTK - E uF11
CP19 step value 1 -400…400 0,0125 5 Hz - oP21
CP20 step value 2 -400…400 0,0125 50 Hz - oP22
CP21 step value 3 -400…400 0,0125 70 Hz - oP23
CP22 DC braking mode 0…506 1 7 - E Pn28
CP23 DC braking time 0,00…100,00 0,01 10 s - Pn30
CP24 LAD load level 0…200 1 140 % - Pn24
CP25 Stall level 0…200 1 200:off % - Pn20
CP26 Speed search condition 0…31 1 8 - E Pn26
CP27 Motor protect. function response 0…6 1 6 Pn14
CP28 Motor protection mode 0…1 1 1 dr11
CP29 motorprot. rated current 0,0…370,0 0,1 LTK A dr12
CP30 ANOUT1 function 0…26 1 2 E An31
CP31 ANOUT1 gain -20,00…20,00 0,01 1 An33
CP32 Condition SB0 0…101 1 20 E do00
CP33 Condition SB2 0…101 1 4 E do02
CP34 comparison level 2 ±30000,00 0,01 100,00 LE02
CP35 AN1 interface selection 0…2 1 0 E An00
CP36 select 50Hz/60Hz mode 0…1 1 0 E Ud06
CP37 warning dOH stop. mode 0…8 1 7 Pn12
CP38 Inverter address 0…239 1 0 Sy06
CP39 last error 0…255 1 0 E, R In24
CP40 parameter set copy function -4…7 1 0 Fr01
CP48 Software version x.x.x.x LTK R In06
LTK=depending on power unit; E=ENTER-Parameter; R=read only

Other manuals for KEB COMBIVERT G6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT G6 and is the answer not in the manual?

KEB COMBIVERT G6 Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT G6
CategoryDC Drives
LanguageEnglish

Related product manuals